BKM Logo
Composite Road Mats

Composite Road Mats

Composite Construction Mats
cellular core heavy duty ground protection mat
Composite Construction Mats
Composite Construction Mats
Composite Construction Mats
cellular core heavy duty ground protection mat
Composite Construction Mats
Composite Construction Mats

Large cellular panels for continuous temporary transport routes

A temporary transport road needs a continuous layout from its entrance to its final delivery point. BKM supplies large-format composite road mats with overlapping edges and mechanical connections for assessed construction traffic. The cellular panel system gives road planners a defined installed module for calculating straight sections, turns and the additional coverage needed at road entries.

Reference Price Light $37-80 | Heavy $343-730 | Cellular Core $1500-2100 Price Varies by Specs
Min. Order Qty Black 50 pcs | Colors 300 pcs | In-stock: 1 pc
WhatsApp Us
Quality Certified
Global Shipping
Custom OEM/ODM

Product Specifications

Detailed technical specifications

Key Features & Advantages

Cover more ground with each placed panel. The reference cellular panel provides 9.31 m² of usable coverage. This large footprint helps buyers plan a continuous road with fewer individual panels than a small portable format covering the same area.

Build around a connected edge system. Overlapping edges and matching bolts form the joints between panels. We review the edge arrangement and connections together so the road layout follows the actual module.

Use structural depth efficiently. The 102 mm cellular body combines outer faces with internal reinforcement. The structure is intended for mechanically installed access systems rather than treating the panel as a thick solid slab.

Plan road entries with the main route. The panel depth creates a change in level at the road entrance. Include appropriate transitions, vehicle clearance and the approach surface in the supply brief.

Expand for turns and passing points. A road order can include widened sections where traffic changes direction or vehicles need space to pass. Quote these areas from the drawing rather than relying on the straight-road quantity.

Recover a road asset after the project. Polymer composite panels can be disconnected, cleaned, inspected and stored for reuse. The recovered inventory supports later access work instead of becoming fill material left on site.

Applications

Construction delivery roads. Create an assessed route for repeated deliveries between an established road and a project receiving area. Include bends and entry geometry in the panel schedule.

Remote utility access. Extend a connected transport route toward the work location, with suitable supporting ground and the selected vehicle duty confirmed.

Temporary industrial circulation. Provide removable road sections around temporary receiving and service areas. Widen the layout where the traffic arrangement requires it.

Project roads intended for recovery. Specify the roadway and its dismantling sequence together where the site must be cleared after temporary access ends.

Reference large-format cellular panel configuration for the selected project. Confirm the material grade, connections and supplied drawing with the order.

Specification Reference configuration Order consideration
Material family Polymer composite Confirm the selected material grade
Transport dimensions 4350 × 2430 mm Use for pack and unloading planning
Installed dimensions 4160 × 2240 mm Use the approved layout for coverage
Usable panel area 9.31 m² Rounded reference area
Total thickness 102 mm Provide an appropriate entry transition
Reference panel weight 465 kg Mechanical handling required
Connection provision 8 bolts per panel Confirm final points and quantities
Reference color Beige Alternative requirements need review

The body structure, soil support and vehicle duty must be reviewed together. The dimensions and weight do not establish an unconditional load capacity.

Company Certifications
Quality Assurance

Certified for Global Standards

Each batch undergoes thorough inspection on the shop floor. Raw material is tested upon arrival, as well as finished parts upon completion. Anything failing to conform to specifications is not shipped out.

ISO 9001 Quality Management

ISO 9001:2015 certification requires written processes, production control measures, and traceability of the process from initial raw material to finished part. More critically, ISO helps us maintain tolerances across multiple batches, rather than just in theory.

Food-Grade FDA Compliance

In cases of applications involving food production, only selected types of HDPE and UHMWPE materials which conform to FDA food-grade standards are used. These grades are usually utilized in cutting surfaces, guides, and wear parts.

RoHS Compliant Manufacturing

Materials comply with RoHS environmental regulations in terms of substance content restrictions. This is ensured by monitoring the components of the material, rather than the finished part.

Traceable Material Test Reports (MTR)

Material test reports available upon request include mechanical properties such as tensile strength and impact value, as well as wear information and dimensional checks.

Industry Solutions

Application Areas

Our ground protection and engineering plastic solutions are trusted across a wide range of demanding industries and environments.

Frequently Asked Questions

The reference panel measures 4350 × 2430 mm for transport, while its installed module is 4160 × 2240 mm. The overlapping arrangement accounts for that distinction. Use transport dimensions for loading and the approved installed layout for road quantities.

With the 4.16 m installed dimension across the road and a 2.24 m module along it, the geometric calculation is 100 ÷ 2.24, rounded up to 45 panels. This excludes entries, turns, passing areas and spares, and does not establish an adequate traffic width.

Forty-five reference panels at 465 kg each total 20,925 kg before hardware and packing. Confirm the final gross mass and loading arrangement with the quotation; this calculation is not a container-capacity statement.

Eight bolts per panel is the reference provision. The final component list must follow the connection drawing, including joint positions, boundary conditions and any shared points. Use the multiplication only as an initial allowance.

Agree the corner geometry and any special pieces before supply. Cutting a structural cellular panel can alter its edges and connections, so a site modification should not substitute for an approved roadway detail.

Layering changes the support and connection arrangement and requires its own review. Provide the ground information and intended traffic so the access design can address the cause of settlement rather than assuming another layer creates a rated road.

Compare usable installed area, material grade, structural depth, panel weight, connections, entry pieces and handling requirements. Ask each supplier to quote the same route drawing and vehicle duty so a lower panel price is not confused with a lower complete-road cost.

Send Us a Quick Inquiry

Get a response from our team within one business day.

By submitting, you agree to be contacted regarding your inquiry.

Submitting...

Related Products

Ready to Order or Need a Custom Quote?

Our team is ready to help you with product selection, specifications, and custom manufacturing solutions.

Browse All Products
Chat on WhatsApp